IO-Link Application¶
iqmaxrefdes23 communicates with an IO-Link Master on COM3 transmission rate (230,4 kbit/s).
Note
When a device is switched to IO-Link SIO mode, sensors chip is switched to shutdown mode, microcontroller fall into HALT and restarting operation upon wake-up interrupt signal.
Process Data In¶
- Byte (MSB): Light intensity (from 0 to 255).
- Byte (LSB): [.......F - light intensity switch-point flag (1bit)].
Process Data Out¶
Be absent.
Commands¶
Can be run by IO-Link Index 0x0002:
Value | Description |
---|---|
128 (0x80) | Device Reset |
160 (0xA0) | Tech-in light intensity switch-point level |
Parameters¶
IO-Link index | Mode | Description | Default value |
---|---|---|---|
16 (0x0010) | read-only | Vendor Name | Renesas Electronics Europe GmbH |
17 (0x0011) | read-only | Vendor Text | Major supplier of semiconductor solutions |
18 (0x0012) | read-only | Product Name | Santa Cruz (MAXREFDES23#) |
19 (0x0013) | read-only | Product ID | MAXREFDES23 |
20 (0x0014) | read-only | Product Text | IO-Link Light Sensor |
23 (0x0017) | read-only | Firmware Revision | v1.1 |
256 (0x0100) | read/write | Ambient light switch-point level | 128 (0x80) |
257 (0x0101) | read/write | Ambient light switch-point hysteresis | 16 (0x10) |
258 (0x0102) | read/write | MAX44008EDT+ sensors chip sensivity | 1 (0x01) |
259 (0x0103) | read-only | MAX44008EDT+ sensors chip temperature | unknown |
Events¶
Event code | Description |
---|---|
0x1801 | Occurred when a light intensity is very low, see Sensor Logic |