Sensor Logic¶
In iqmaxrefdes23 have been implemented simple switch-point hysteresis logic and additionally can be configured as normally closed or normally opened.
By default light switch-point settings (255 is the maximal value):
What | SP (Level) | Hysteresis | Mode |
---|---|---|---|
Light intensity | 128 (0x80) | 16 (0x10) | Normally closed |
Darkness control | 16 (0x10) | 4 (0x04) | Normally opened |
Note
When a device is in IO-Link OPERATE mode, light intensity switch-point flag indicated on digital output channel (red LED).